IoT Controller.Connect field signals.
Control with context.

Hitelecom controller labelled HD20-4021GD, original product image supplied for the HD20-4000 series page
HD20-4021GD · illustrated model

The Hitelecom HD20-4000 series combines field data acquisition, equipment monitoring and control in a compact RTU. The 4DO + 4DI + 4AI reference configuration connects digital equipment states, external analogue measurements and compatible control circuits. Edge processing, local, remote and condition-based control, and remote configuration and firmware upgrades support the installation throughout its operating life. View uploaded monitoring data online in Hitelecom Cloud and receive alerts when configured thresholds are exceeded.

4DO + 4DI + 4AIReference I/O configurationDigital control, state inputs and analogue measurements
Local · Remote · ConditionalControl modesMatch the action to the equipment workflow
Hitelecom CloudOnline data and configured alertsView measurements and respond to threshold events

KEY FEATURES

Field data.
Connected control.

Connect four reference digital outputs, four digital inputs and four analogue inputs to a defined equipment workflow, with online monitoring and configured threshold alerts in Hitelecom Cloud.

Digital and analogue I/O together

The 4DO + 4DI + 4AI reference configuration combines four control outputs, four equipment-state inputs and four analogue measurement inputs. Build the point allocation around the actual instrument and equipment signal list.

Edge processing at the equipment

Process field information close to its source for equipment monitoring and condition-based actions. The project configuration defines the signal interpretation, control conditions and permitted responses.

Local, remote and condition-based control

Use the operating mode that fits the task: local operation, remote supervision or an action linked to a configured condition. Define priorities and equipment feedback for the selected control arrangement.

Master/slave operating modes

Support project-defined device coordination with master/slave working modes. The selected interface, communication protocol and device roles form part of the integration configuration.

Online monitoring and threshold alerts

Use Hitelecom Cloud to view uploaded monitoring data online and receive alerts when configured thresholds are exceeded. Map equipment states, measurement units and alert recipients to the operating workflow.

Remote configuration and upgrades

Adjust supported settings and upgrade device firmware remotely. Plan maintenance around the installed configuration, software version and the site’s operating procedure.

Hardware and software watchdogs

Dual watchdog mechanisms support recovery from defined software or system faults. Recovery behaviour and output states are part of the device configuration and commissioning checks.

Compact integration for field equipment

Bring monitoring and control into equipment rooms, service cabinets and distributed installations with a compact controller design. Select the power, enclosure and wiring arrangement for the site.

FIELD INTERFACES

Read the signal.
Choose the action.

The reference configuration provides 4 digital outputs, 4 digital inputs and 4 analogue inputs. Select electrical compatibility, output circuits and point allocation for the supplied version.

4 × DO

Digital outputs

Issue defined control commands through four digital outputs in the reference configuration. Select the output electrical type and connect each point to a compatible equipment control circuit.

  • Equipment enable requests
  • Valve actuator command interfaces
  • Auxiliary indication circuits
4 × DI

Digital inputs

Acquire four equipment-state signals in the reference configuration. Define the electrical compatibility, normal state and operating meaning of each digital input.

  • Running and fault indications
  • Valve end-position feedback
  • Level, door or maintenance switches
4 × AI

Analogue inputs

Acquire four analogue measurement signals in the reference configuration. Match each external transmitter to the supplied input range, engineering units and scaling.

  • Pressure and level transmitters
  • Temperature transducer outputs
  • Other compatible analogue instruments

MONITORING & CONTROL

Acquire. Decide.
Act with feedback.

Combine data acquisition with local, remote and condition-based control. Verify the equipment state separately from the requested output action.

01

Acquire the field signals

Connect equipment-state signals and compatible analogue transmitter outputs. Give each point an asset identity, signal definition, engineering range and normal state.

02

Apply the operating logic

Select local, remote or condition-based operation for each permitted action. Specify the initiating condition, command priority and equipment response required by the project.

03

Issue the permitted action

Send defined digital commands through electrically compatible control interfaces. The host equipment retains its sequencing, interlocks and independent protection functions.

04

Observe and verify the result

Check available equipment feedback independently of the output command. View uploaded states and measurements in Hitelecom Cloud and verify configured threshold alerts during commissioning.

APPLICATIONS

Connected equipment.
Across the operation.

Eight application areas, with five engineering tasks in each, show how the controller can connect monitoring points and permitted control actions. These 40 tasks are selection examples, not 40 simultaneous channels or a claim that every task is fitted in one device. Allocate the selected signals against the 4DI / 4AI / 4DO reference configuration; larger point lists may require another configuration or additional controllers. External instruments, communication interfaces and load-control equipment are selected for the project.

8 application areas / 40 project tasks

Representative environments. Field instruments and control circuits are selected for each installation.

01Vending & Self-Service Equipment5
Unbranded vending machines in an indoor self-service area
Unbranded vending machines in an indoor self-service area

Connect selected machine states, external measurements and auxiliary control circuits for service visibility across unattended retail equipment. Define the interface with the machine supplier; dispensing sequences, payment and transaction processing remain with their dedicated systems.

Machine availability and service faults

Unbranded vending machines in an indoor self-service area
Unbranded vending machines in an indoor self-service area

Read available ready, running or fault signals to distinguish a machine that is available for service from one requiring inspection.

Field interface
Allocate compatible DI points to the selected machine-state outputs.
Control scope
Use a DO only for an auxiliary command expressly supported by the machine’s external interface.
Verification
Check every state against the machine display and source signal; connectivity alone does not establish machine availability.
Discuss this application ↗

Refrigerated compartment conditions

Refrigerated vending compartment with an external temperature probe
Refrigerated vending compartment with an external temperature probe

Collect external temperature-transmitter signals from selected compartments to support cold-storage condition monitoring.

Field interface
Allocate AI points to compatible conditioned temperature signals and define each compartment’s range.
Control scope
Configure threshold alerts; any supervisory enable request must use the refrigeration unit’s approved interface.
Verification
Compare readings with the source instruments and verify the complete alert workflow; refrigeration protection remains with the unit.
Discuss this application ↗

Service-door and access events

Vending-machine service door and contact switch
Vending-machine service door and contact switch

Identify service-door openings and maintenance-mode states under the correct machine asset.

Field interface
Use compatible DI signals from the selected door switches or service-state contacts.
Control scope
Assign an auxiliary service indication where the machine interface permits it.
Verification
Check normal-state logic and planned maintenance events; an access event does not by itself identify or authorize a person.
Discuss this application ↗

Condensate and leakage supervision

Condensate tray and drain tubing in a vending-machine service bay
Condensate tray and drain tubing in a vending-machine service bay

Combine a selected leakage event with available drainage-equipment feedback to support service response inside a vending installation.

Field interface
Allocate DI points to the compatible leakage contact and required drain-unit status signals.
Control scope
Connect a permitted drainage or auxiliary indication request through the documented control circuit.
Verification
Test the physical leakage indication, local drainage operation and reported equipment state.
Discuss this application ↗

Auxiliary lighting and service indication

Illuminated vending display and separate service indicator
Illuminated vending display and separate service indicator

Add defined local or remote requests for machine lighting or a service-status indicator through compatible auxiliary circuits.

Field interface
Allocate DO points and available DI feedback for the selected auxiliary function.
Control scope
Use the agreed local, remote or condition-based operating priority.
Verification
Verify the actual lamp or indicator response and local override; keep the vending and payment controller’s functions separate.
Discuss this application ↗
02Smart Shelving & Retail Fixtures5
Retail shelving and store fixtures in an unbranded shop interior
Retail shelving and store fixtures in an unbranded shop interior

Bring selected shelf-equipment states and external measurements into retail operations monitoring. Interface selection is project-specific; this does not imply native compatibility with electronic price-label networks or inventory software.

Shelf-controller service states

Retail shelving and store fixtures in an unbranded shop interior
Retail shelving and store fixtures in an unbranded shop interior

Monitor compatible ready and fault outputs from an electronic shelf controller or powered retail fixture.

Field interface
Allocate DI points to documented equipment-state signals.
Control scope
Use an auxiliary service request only where the host controller provides an approved external command interface.
Verification
Check each state against the host system and its interface documentation; price data and label updates use the dedicated shelf system.
Discuss this application ↗

Shelf-zone environmental measurements

Temperature and humidity probe beside a retail shelf zone
Temperature and humidity probe beside a retail shelf zone

Associate selected external temperature or humidity measurements with a defined shelf zone or retail display area.

Field interface
Use compatible analogue transmitter outputs within the selected AI allocation.
Control scope
Configure monitoring limits and the associated notification workflow.
Verification
Verify units, scaling and sensor placement; the measured zone must represent the goods or area being supervised.
Discuss this application ↗

Fixture power-supply alarms

Low-voltage power supply in a retail-fixture service compartment
Low-voltage power supply in a retail-fixture service compartment

Identify selected alarm states from a shelf rail or retail fixture’s external power supply.

Field interface
Connect compatible power-supply alarm contacts to DI points.
Control scope
Operate an approved auxiliary indicator if the service procedure requires one.
Verification
Test the source alarm and distinguish supply failure from controller power loss or communication loss.
Discuss this application ↗

Display-cabinet service access

Retail display-cabinet service door and latch contact
Retail display-cabinet service door and latch contact

Bring selected cabinet-door and maintenance contacts into a store’s equipment monitoring view.

Field interface
Allocate DI points to compatible service-door or maintenance-mode signals.
Control scope
Provide a suitable local service indication through an agreed auxiliary circuit.
Verification
Confirm the cabinet identity, normal states and event meanings with store operations.
Discuss this application ↗

Retail-fixture auxiliary enable

Retail display lighting and a ventilation accessory
Retail display lighting and a ventilation accessory

Supervise an allowed enable request for a selected fixture accessory, such as display lighting or a ventilation unit.

Field interface
Use compatible DO command circuits and available DI operating feedback.
Control scope
Define local priority and the permitted action independently of the shelf-label or inventory system.
Verification
Test command, actual response and local override; output activation alone is not proof that the accessory is operating.
Discuss this application ↗
03PLC & Existing Control Systems5
Industrial control cabinet with PLC equipment and labelled terminal wiring
Industrial control cabinet with PLC equipment and labelled terminal wiring

Connect the RTU to documented auxiliary signals from an existing PLC-controlled system. The PLC retains its process sequence, interlocks and safety functions; selected physical interfaces and protocols must be established for each integration.

PLC run and summary-fault visibility

Industrial control cabinet with PLC equipment and labelled terminal wiring
Industrial control cabinet with PLC equipment and labelled terminal wiring

Publish selected PLC running and summary-fault states for remote operations and maintenance review.

Field interface
Allocate DI channels to compatible auxiliary state outputs made available by the PLC system.
Control scope
Keep any permitted supervisory request separate from the PLC’s core sequence and protections.
Verification
Validate state meanings and source wiring with the control-system documentation.
Discuss this application ↗

Selected sequence-state acquisition

Conveyor equipment with discrete process-state sensors
Conveyor equipment with discrete process-state sensors

Read a small set of discrete process or sequence states so remote operators can interpret where the equipment is in its operating cycle.

Field interface
Allocate up to four reference DI points to the chosen state signals.
Control scope
Use acquired states for monitoring and only the agreed supervisory conditions.
Verification
Check that the selected states are distinct and remain meaningful during start-up, maintenance and abnormal operation.
Discuss this application ↗

External measurement monitoring

Pressure and temperature instruments on a PLC-controlled process skid
Pressure and temperature instruments on a PLC-controlled process skid

Read compatible analogue transmitter signals associated with a PLC-controlled process for a separate remote monitoring view.

Field interface
Allocate up to four reference AI points to the selected instruments; establish signal conditioning and loading compatibility.
Control scope
Use measurement limits for notifications or permitted supervisory conditions.
Verification
Compare displayed values with their source instruments; agree any shared-signal wiring design before connection.
Discuss this application ↗

Supervisory enable requests

Machine operator panel with auxiliary control buttons
Machine operator panel with auxiliary control buttons

Provide a defined external request to an existing PLC input when the control design permits supervisory enable or inhibit commands.

Field interface
Connect compatible DO points to the PLC system’s approved command-input circuit and allocate available status feedback.
Control scope
The PLC evaluates the request against its own operating conditions and priorities.
Verification
Test accepted, rejected and cancelled requests; receipt of a command is separate from the resulting equipment state.
Discuss this application ↗

Auxiliary acknowledgement and service requests

Auxiliary service-request and acknowledgement controls on a cabinet
Auxiliary service-request and acknowledgement controls on a cabinet

Provide an agreed acknowledgement or maintenance request through a documented external PLC interface.

Field interface
Allocate compatible DO command points and the required DI acknowledgement or service feedback.
Control scope
Limit the function to the approved auxiliary action; protection resets and emergency controls follow the host system design.
Verification
Verify command duration, state transition and actual acknowledgement with the control engineer.
Discuss this application ↗
04Environmental Monitoring Facilities5
Environmental treatment facility with process instruments and pipework
Environmental treatment facility with process instruments and pipework

Connect compatible external instruments and auxiliary facility signals for environmental operations. The selected probes and transmitters define the measured substances, ranges and performance; the RTU acquires their available signals.

Air-quality transmitter acquisition

Environmental treatment facility with process instruments and pipework
Environmental treatment facility with process instruments and pipework

Bring selected gas or air-quality transmitter outputs into a location-based monitoring view.

Field interface
Allocate compatible AI points to the chosen instrument outputs and engineering units.
Control scope
Use configured concentration or condition limits for notifications and any agreed auxiliary request.
Verification
Confirm the instrument’s target variable, range and installation suitability; the controller itself is not a gas detector.
Discuss this application ↗

Water-quality measurement points

Water-quality instrument sampling rack and flow cells
Water-quality instrument sampling rack and flow cells

Collect selected conditioned outputs from external water-quality instruments for treatment or discharge supervision.

Field interface
Match each AI channel to the instrument’s supported output and scaling.
Control scope
Use configured limits for operator attention or a permitted supervisory function.
Verification
Check readings against the source instrument and its maintenance procedure; a measured value does not establish regulatory compliance.
Discuss this application ↗

Treatment-unit running and fault states

Treatment skid with pump and local operating indications
Treatment skid with pump and local operating indications

Identify whether a selected treatment skid or auxiliary unit reports running, stopped or faulted.

Field interface
Allocate DI points to compatible unit-status signals.
Control scope
Use an allowed supervisory enable request through the treatment unit’s own controller.
Verification
Compare the reported states with the source equipment and retain its process protections.
Discuss this application ↗

Filter and extraction-system condition points

Filter housing and extraction duct with pressure sensing points
Filter housing and extraction duct with pressure sensing points

Monitor a selected differential-pressure measurement or filter switch alongside available extraction-unit feedback.

Field interface
Use compatible AI or DI signals from the chosen pressure instrument and unit-state contacts.
Control scope
Configure maintenance notifications or an agreed auxiliary indication.
Verification
Verify the measurement or switch setting; differential pressure alone is not a verified airflow or removal-efficiency measurement.
Discuss this application ↗

Sampling and auxiliary pump supervision

External sampling pump and instrument tubing
External sampling pump and instrument tubing

Connect operating feedback and permitted requests for an external sampling pump or instrument accessory.

Field interface
Allocate compatible DO command points and DI running or fault feedback.
Control scope
Follow the instrument package’s allowed sequence and local priority.
Verification
Test actual sample-path or equipment feedback where provided; a command alone does not confirm that a representative sample was collected.
Discuss this application ↗
05Agriculture & Irrigation5
Greenhouse irrigation and fertigation equipment
Greenhouse irrigation and fertigation equipment

Connect selected environmental transmitters, irrigation equipment states and permitted auxiliary commands. Water delivery and crop-management decisions depend on the selected instruments and the site’s agronomic and hydraulic design.

Greenhouse condition monitoring

Greenhouse irrigation and fertigation equipment
Greenhouse irrigation and fertigation equipment

Collect external temperature and humidity signals at selected greenhouse zones for operating visibility.

Field interface
Allocate compatible AI points to the required conditioned transmitter outputs.
Control scope
Configure limits and permitted auxiliary ventilation requests within the greenhouse control design.
Verification
Verify sensor placement and readings against the source instruments; keep equipment protection and local control priorities intact.
Discuss this application ↗

Irrigation valve requests and feedback

Motorized irrigation valve and distribution manifold
Motorized irrigation valve and distribution manifold

Keep a requested irrigation-valve action separate from the available valve-position or line-state feedback.

Field interface
Allocate compatible DO command circuits and DI feedback points for the selected valves.
Control scope
Use local, remote or condition-based requests under the approved irrigation sequence.
Verification
Verify local override and physical response; output activation alone does not confirm valve travel or water delivery.
Discuss this application ↗

Irrigation pressure supervision

Pressure instruments at an irrigation distribution header
Pressure instruments at an irrigation distribution header

Monitor selected compatible pressure-transmitter signals around an irrigation supply or distribution point.

Field interface
Use AI points with engineering ranges matched to the external pressure instruments.
Control scope
Configure pressure notifications or a permitted pump supervisory request.
Verification
Compare readings with the source instruments and confirm actual pump feedback; pressure monitoring does not replace hydraulic protection.
Discuss this application ↗

Water-storage level and pump states

Farm water-storage tank and adjacent transfer pump
Farm water-storage tank and adjacent transfer pump

Combine an external storage-level measurement with selected pump running or fault signals.

Field interface
Allocate a compatible AI level signal and the required DI equipment-state points.
Control scope
Use an agreed pump or valve request within the local water-management design.
Verification
Test level scaling, state feedback and recovery behaviour; independent overflow and dry-run protection remain with the appropriate equipment.
Discuss this application ↗

Fertigation package operating points

Fertigation dosing package in a greenhouse service area
Fertigation dosing package in a greenhouse service area

Acquire selected conditioned measurement outputs or service-state contacts from an external dosing or fertigation package.

Field interface
Match available AI and DI points to the package signal schedule.
Control scope
Limit any command to a documented supervisory interface supported by the package.
Verification
Verify units, equipment feedback and permitted command scope with the package supplier; the RTU does not establish a dosing recipe.
Discuss this application ↗
06Unattended & Remote Stations5
Remote telecommunications equipment site
Remote telecommunications equipment site

Bring cabinet events, external measurements and auxiliary operating requests into the maintenance workflow for distributed sites. Select power, communication and protective installation arrangements against the actual site conditions.

Cabinet access and service state

Remote telecommunications equipment site
Remote telecommunications equipment site

Associate selected door-open and maintenance-mode events with the correct remote cabinet or station.

Field interface
Allocate DI points to compatible access and service-state contacts.
Control scope
Use a suitable auxiliary indication circuit where required by the station procedure.
Verification
Test normal-state wiring and site identity; access authorization remains a separate function.
Discuss this application ↗

Station power-system alarms

Backup power equipment and alarm contacts at a remote station
Backup power equipment and alarm contacts at a remote station

Read selected external power-supply or backup-system alarm contacts for remote service response.

Field interface
Allocate compatible DI points to the documented alarm outputs.
Control scope
Limit auxiliary control to functions permitted by the external power equipment.
Verification
Test source alarms, controller power loss and lost communication as separate conditions.
Discuss this application ↗

Cabinet ventilation supervision

Ventilation fan and environmental probe in a field cabinet
Ventilation fan and environmental probe in a field cabinet

Combine a compatible external temperature measurement with fan running or fault feedback.

Field interface
Use AI for the conditioned temperature signal and DI for the selected equipment states.
Control scope
Connect a permitted fan-enable request through its approved control circuit.
Verification
Check physical fan operation, local priority and the agreed response after restart.
Discuss this application ↗

Conditioned battery or utility measurements

External battery-monitoring transducer near a station battery bank
External battery-monitoring transducer near a station battery bank

Read selected analogue outputs from external battery-monitoring or station utility transducers.

Field interface
Match AI channels to the external instrument’s isolated or conditioned output specification.
Control scope
Use configured measurement limits for online notifications.
Verification
Compare scaling with the source instrument; do not connect an unverified battery or power circuit directly to an AI terminal.
Discuss this application ↗

Site leakage and auxiliary equipment states

Leakage sensing area on a remote equipment-room floor
Leakage sensing area on a remote equipment-room floor

Bring a leakage contact and selected station auxiliary states into the same site monitoring view.

Field interface
Allocate compatible DI signals and any required conditioned AI measurement within the reference point budget.
Control scope
Use notifications or an approved auxiliary request under the station operating procedure.
Verification
Verify the source event, actual equipment response and the agreed communication-loss behaviour.
Discuss this application ↗
07Industrial Equipment & Auxiliary Packages5
Industrial machine and auxiliary equipment on a manufacturing floor
Industrial machine and auxiliary equipment on a manufacturing floor

Connect selected machine and package signals for operating visibility and permitted supervisory control. The host equipment retains its process control, interlocks and independent protective functions.

Machine run and fault monitoring

Industrial machine and auxiliary equipment on a manufacturing floor
Industrial machine and auxiliary equipment on a manufacturing floor

Make selected auxiliary machine states available for production support and service assessment.

Field interface
Allocate compatible DI points to the documented running, ready or fault signals.
Control scope
Use an output only for a machine function expressly intended for external supervision.
Verification
Validate state meanings with the machine supplier and compare reported states with the actual equipment.
Discuss this application ↗

Compressor package supervision

Industrial compressor package and local operating indicators
Industrial compressor package and local operating indicators

Associate selected running, loading or trip indications with the correct compressor asset.

Field interface
Allocate DI points to the available compatible package-state signals.
Control scope
Provide a permitted enable request through the package’s approved external control circuit.
Verification
Check actual running feedback, local mode and the supplier’s restart and trip-reset policy.
Discuss this application ↗

Cooling and circulation auxiliaries

Cooling circulation pump and heat-exchanger pipework
Cooling circulation pump and heat-exchanger pipework

Connect compatible temperature or pressure measurements with available pump or fan status signals for a cooling package.

Field interface
Allocate the required AI measurements and DI feedback within the reference I/O budget.
Control scope
Use defined conditions for notifications or a permitted supervisory enable request.
Verification
Verify measured values and physical equipment feedback; retain the package’s independent process protections.
Discuss this application ↗

Actuator command and position feedback

Industrial valve actuator with end-position switch housing
Industrial valve actuator with end-position switch housing

Monitor the relationship between an approved actuator command and its available end-position signals.

Field interface
Use compatible DO command interfaces and DI position contacts for the selected actuator.
Control scope
Apply the permitted movement sequence and local override priority.
Verification
Test full travel and the available position feedback; the output state alone does not confirm actuator position.
Discuss this application ↗

Maintenance-required and service indication

Machine maintenance indicator and service-access panel
Machine maintenance indicator and service-access panel

Identify selected maintenance or service-mode signals so operators can interpret equipment events during planned work.

Field interface
Allocate compatible DI points and an approved auxiliary indication output if needed.
Control scope
Keep service indication separate from machine sequencing and protection reset functions.
Verification
Test normal operation, active fault and planned maintenance states using the agreed service procedure.
Discuss this application ↗
08Transport & Roadside Facilities5
Roadside infrastructure cabinet at a transport facility
Roadside infrastructure cabinet at a transport facility

Monitor selected roadside and transport-facility support equipment through documented auxiliary interfaces. Traffic-signal phases, railway interlocking, emergency controls and other safety functions remain with their dedicated systems.

Roadside cabinet access and faults

Roadside infrastructure cabinet at a transport facility
Roadside infrastructure cabinet at a transport facility

Identify compatible cabinet-door and equipment-fault signals at a defined roadside asset.

Field interface
Allocate DI points to the selected access and auxiliary fault contacts.
Control scope
Use an approved local service indicator where the maintenance procedure requires one.
Verification
Verify physical source events and asset identity; an IoT notification is not a safety-system response.
Discuss this application ↗

Cabinet thermal and ventilation conditions

Roadside equipment-cabinet ventilation fan and temperature probe
Roadside equipment-cabinet ventilation fan and temperature probe

Connect external temperature measurements with available ventilation-unit feedback for a roadside equipment cabinet.

Field interface
Use compatible AI transmitter outputs and DI fan-state signals.
Control scope
Provide a permitted auxiliary ventilation request through the documented control interface.
Verification
Verify actual fan response and local priority, and select the protective installation against the site exposure.
Discuss this application ↗

External weather-instrument signals

External weather instruments beside a transport facility
External weather instruments beside a transport facility

Acquire selected conditioned outputs from site weather instruments for transport-facility operating awareness.

Field interface
Match AI channels to the chosen instruments, units and working ranges.
Control scope
Configure monitoring limits and the associated notification workflow.
Verification
Validate source readings and placement; observation signals do not constitute a weather forecast or an automatic road-closure decision.
Discuss this application ↗

Drainage support-equipment supervision

Transport-facility drainage sump and pump installation
Transport-facility drainage sump and pump installation

Combine selected level or leakage events with drainage-pump running and fault indications at a transport facility.

Field interface
Allocate compatible AI or DI instruments and the required DI pump feedback.
Control scope
Use an agreed supervisory request through the pump-control system.
Verification
Check actual level and pump feedback; flood protection and local pump safeguards remain with the appropriate systems.
Discuss this application ↗

Transport-facility auxiliary enable

Service lighting at a transport maintenance facility
Service lighting at a transport maintenance facility

Provide a defined local or remote request for a supported non-safety auxiliary, such as service lighting or an equipment-cabinet accessory.

Field interface
Use compatible DO command circuits and available DI operating feedback.
Control scope
Limit the action to the documented auxiliary scope and local operating priority.
Verification
Test the command and physical result; do not use the RTU to replace traffic-control, emergency-stop or railway safety functions.
Discuss this application ↗

CONFIGURATION & SPECIFICATIONS

A defined configuration.
Clear engineering boundaries.

The HD20-4000 series supports project-selected I/O arrangements. The reference configuration below is 4DO + 4DI + 4AI. The product image shows a unit labelled HD20-4021GD; the final ordering code, fitted interfaces and electrical limits follow the agreed configuration-specific specification.

Series & Field I/O

HD20-4000 Series — Series & Field I/O
Product familyHD20-4000 Series IoT Controller / RTU
Illustrated modelHD20-4021GD; 4G-labelled device
Reference I/O configuration4 digital outputs + 4 digital inputs + 4 analogue inputs
Digital inputs4 channels in the reference configuration. Request the input electrical type, thresholds and wiring specification.
Digital outputs4 channels in the reference configuration. Request the output type, permitted load and switching-interface specification.
Analogue inputs4 channels in the reference configuration. Request the supported signal range, accuracy conditions and scaling specification.

Processing & Control

HD20-4000 Series — Processing & Control
Edge processingSupported; application logic and signal interpretation follow the selected configuration.
Control modesLocal / remote / condition-based
Operating rolesMaster/slave working modes; interface, protocol and role selection are defined for the project.
WatchdogsSoftware and hardware watchdog mechanisms
Sampling, reporting and responseDefine input sampling, data reporting, event processing and control-response requirements separately.
Start-up and lost-link behaviourSpecify output states, permitted local actions and recovery behaviour for the delivered configuration.

Connectivity & Platform

HD20-4000 Series — Connectivity & Platform
Cellular variant shown4G; select the regional module, bands, SIM service and antenna arrangement for the installation.
Hitelecom CloudOnline viewing of uploaded monitoring data and alerts above configured thresholds.
Customer platformProject-specific integration; agree the supported device interface, protocol and data mapping.
Remote configurationSupported for the applicable device settings.
Remote firmware upgradeSupported; use the approved firmware and maintenance procedure for the supplied configuration.

Power & Installation

HD20-4000 Series — Power & Installation
Power supplyRequest the rated input range, polarity, peak/typical consumption and wiring requirements.
Form and installationCompact enclosure; select mounting, cable routing and service clearance for the installation.
Dimensions and massRefer to the configuration-specific mechanical drawing and product specification.
External equipment interfacesMatch the controller I/O electrical specification to each instrument, actuator or load-control circuit.

Environment & Documentation

HD20-4000 Series — Environment & Documentation
Installation environmentSelect the device and any protective cabinet against the site temperature, humidity and exposure conditions.
Ingress protectionRequest the rating and installation conditions for the supplied device configuration.
Commissioning informationSignal schedule, control permissions, equipment feedback, remote settings and recovery checks.
Conformity documentationRequest model- and destination-specific declarations or test documentation for the ordered version.

Select external instruments, loads and control circuits against the supplied electrical specification. Independent equipment protection and required safety functions remain part of the installation design.

PLATFORM & INTEGRATION

Your field equipment. Visible in Hitelecom Cloud.

View uploaded monitoring data online, follow equipment states and receive alerts when configured thresholds are exceeded. Connect the controller’s digital and analogue points to meaningful asset names, units and operating conditions. Customer-platform integration can be scoped around the selected device interface and data exchange requirements.

Online data: bring equipment states and external measurement values into the selected monitoring view, with units and update behaviour defined for each point.

Threshold alerts: set the relevant monitoring limits and notification workflow. Verify the alert condition, recipient and delivery during commissioning.

Control and integration: agree the permitted remote actions, feedback points and local priorities. Define the protocol and data mapping separately for a customer-platform project.

ANSWERS FOR YOUR PROJECT

Practical questions.
Before you connect.

Answers for interface selection, control modes, cloud access and commissioning.

What is the HD20-4000 series designed to do?

It combines field data acquisition, equipment monitoring and control in an IoT RTU. Digital inputs capture equipment states, analogue inputs receive compatible transmitter signals, and digital outputs connect to permitted control circuits. Edge processing, cloud monitoring and remote maintenance support the operating workflow.

What I/O configuration is available?

The reference arrangement is 4DO + 4DI + 4AI: four digital outputs, four digital inputs and four analogue inputs. The series supports project-selected I/O arrangements. Confirm the channel allocation and obtain the electrical specification for the ordered version. The 40 application tasks are selection examples, not 40 simultaneous channels; a larger point list may need another configuration or additional controllers.

Which signals can the digital and analogue inputs accept?

DI points acquire compatible digital equipment states; AI points acquire compatible analogue transmitter outputs. Match electrical logic, signal ranges, isolation and accuracy conditions to the selected version and external instrument. Provide the instrument output specification during selection. A DO, DI or AI label alone does not establish a relay topology, a voltage/current range or a communication protocol.

Which control modes are supported?

The series supports local, remote and condition-based control. For each action, define the triggering condition, command priority, permitted operating scope and available feedback. Connect outputs through electrically compatible control interfaces. The host equipment retains its sequence, interlocks and independent protection functions.

What do master/slave operating modes mean for integration?

These are working roles for project-defined device coordination. Identify which device initiates an exchange, which responds, and the data or commands involved. Select the actual interface, communication protocol and supported operations for the project. The master/slave description by itself does not establish a serial port type or a particular protocol.

Can I view monitoring data and receive alerts in Hitelecom Cloud?

Yes. Hitelecom Cloud supports online viewing of uploaded monitoring data and alerts when configured thresholds are exceeded. Configure the measurement units, equipment-state meanings, limits and notification workflow for the connected points. Data availability and notification timing depend on the device reporting profile and network connection.

Can the controller be integrated with a customer platform?

Customer-platform, PLC, machine and shelf-system integration is reviewed against the interfaces supported by the selected configuration. Agree the physical connection, protocol where applicable, point definitions, permitted commands and equipment-feedback mapping. Connection to an auxiliary signal does not establish native compatibility with a machine, electronic shelf-label network or payment system.

What is the purpose of the two watchdog mechanisms?

The series uses hardware and software watchdog mechanisms to support recovery from defined faults. They are device-recovery features, not a guarantee of uninterrupted operation or a replacement for equipment protection. Commissioning should verify the applicable reset behaviour and the resulting output states.

Can settings and firmware be maintained remotely?

The series supports remote configuration and remote firmware upgrades. Use the settings and firmware intended for the delivered hardware configuration, and plan maintenance around the site operating procedure. Verify the required settings and device operation after the change.

What happens when communication or power is interrupted?

Local and condition-based control are supported operating modes, but lost-link operation, output fallback states and start-up recovery must be specified for the delivered configuration. A remote command path and an online monitoring view depend on connectivity. Test the agreed interruption and recovery behaviour at commissioning.

Can a digital output directly power a pump, fan or valve?

Select the connection using the output electrical type, the permitted load and the equipment interface. A suitable starter, contactor, intermediate switching device or actuator control circuit may be required. Output activation alone does not prove that a motor is running or a valve has reached position; use available equipment feedback.

What information is needed to select an installation configuration?

Provide the installation country, signal list, instrument output specifications, equipment-control interfaces, required local/remote priorities, power source and site conditions. Include the target platform and the expected behaviour during communication loss or restart. These details establish the I/O allocation, integration scope and any customization requirements.

LET'S TALK ABOUT YOUR PROJECT

Your equipment.
A defined control scope.

Share the instrument outputs, equipment-state points, permitted commands and feedback required at the site. We will review the 4DO + 4DI + 4AI reference allocation against the signal list, define local and remote priorities, and scope Hitelecom Cloud or customer-platform integration.

sales@hitelecom.cn ↗

HD20-4000 Series IoT Controller

Review your brief, then send it with your email app.